| Placid Industries - - Large, high torque Magnetic Particle Brakes, up to 400 Newton-meters torque. |
Magnetic Particle Brake - Specifications |
available. |
![]() |
||
| Torque range = 0.3 - 20 to 400 Newton-meters. View in inch units |
5 solid shaft models![]() |
Typical applications:
|
| |
Mount with shafts horizontally only |
|||
| Model KB-5 | Model PHB-100 |
![]() |
Torque is -
Characteristics - With no electrical excitation, the shaft freely rotates. While the load torque is less than the output torque, the shaft won't rotate. Use the sizing information to select the proper brake. |
| MODEL (Click p/n to view photo) |
Shaft Style |
Torque Range (N-m) |
Coil |
Maximum Overhung Load (Newtons) |
Max. RPM |
Weight (kg.) |
Data Sheets |
Drawings |
Optional Electric Fan Cooling |
||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Input Current (amps) |
|||||||||||
| KB-2.5 | Solid |
0.3 - 20 | 1.3 | 400 | 1800 | 8.6 | KB-2.5 data sheet |
DXF | - | ||
| KB-5 | 0.7 - 50 | 2 | 550 | 14 | KB-5 data sheet |
DXF | |||||
| POB-100 | 0.7 - 95 | 2.4 | 780 | 33 | POB-100 data sheet |
DXF | PFB-100 | ||||
| POB-200 | 3 - 175 | 2.7 | 890 | 53 | POB-200 data sheet |
DXF | PFB-200 | ||||
| POB-400 | 6 - 400 | 3.3 | 1450 | 102 | POB-400 data sheet |
DXF | PFB-400 | ||||
| PHB-50 | Hollow |
2 - 44 | 0.80 | 550 | 1000 | 11 | PHB-50 data sheet |
DXF | - | ||
| PHB-100 | 3.4 - 100 | 2 | 780 | 21 | PHB-100 data sheet |
DXF | |||||
DRAWINGS: PDF-Adobe Acrobat. DXF-Import into your CAD program.
| MODEL | Heat Dissipation (watts) | Compressed Air | |||
|---|---|---|---|---|---|
| at 100 RPM |
at 1000 RPM |
with compressed air or electric fan cooling |
Pressure (Pascals x 1000) |
Flow Rate (meters3 / minute) |
|
| KB-2.5 | 130 | 175 | 260 | 28 | 0.17 |
| KB-5 | 190 | 275 | 425 | 34 | 0.20 |
| POB-100 PFB-100 |
300 | 500 | 800 | 62 | 0.28 |
| POB-200 PFB-200 |
425 | 800 | 1200 | 48 | 0.17 |
| POB-400 PFB-400 |
550 | 1200 | 1900 | 145 | 0.40 |
| PHB-50 | 250 | 400 | - | ||
| PHB-100 | 400 | 800 | |||
![]() |
Compressed air cooling - Clean, dry compressed air may be used to increase cooling. The case has a BSPT threaded port. Solid shaft brakes only. |
Electric Fan - for the same cooling rating as compressed air. Optional, for brakes POB-100, POB-200 & POB-400 only. Use part numbers PFB-100, PFB-200, PFB-400. |
![]() |
|
|
| Signal Isolation Card & Ultrasonic Sensor - For Constant Tension Unwinding & Rewinding | ||
![]() |
The ultrasonic sensor measures the diameter of the roll, to keep tension constant as roll diameter changes. The Signal Isolation Card powers the ultrasonic sensor & scales the ultrasonic's signal, for tension adjustments. The 0-10 volt signal controls your constant current power supply. | |