| Placid Industries - - Large, high torque Magnetic Particle Clutches, up to 300 lb.-feet torque. |
Magnetic Particle Clutch - Specifications |
available. |
![]() |
||
| Torque range = 0.2 - 15 to 300 lb.-feet (3600 lb.-inch) View in metric units |
5 solid shaft models![]() |
Typical applications:
|
| |
![]() Mount with shafts horizontally only |
|||
| Model POC-400 | Model PHC-50 |
![]() |
Torque is -
Characteristics - With no electrical excitation, the input shaft & output shaft freely rotate. While the load torque is less than the output torque, the clutch drives without slip. When the load torque is increased, the clutch will slip smoothly at the torque level set by the coil input current. Use the sizing information to select the proper clutch. |
| MODEL (Click p/n to view photo) |
Shaft Style |
Torque Range (lb.-ft.) |
Coil |
Max. Over- hung Load (lbs.) |
Max. RPM |
Weight (lbs.) |
Data Sheets |
Drawings |
|||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Input Current (amps) |
|||||||||||
| KC-2.5 | solid |
0.2 - 15 | 1.3 | 90 | 1800 | 21 | KC-2.5 data sheet |
DXF | |||
| KC-5 | 0.5 - 38 | 1.9 | 125 | 35 | KC-5 data sheet |
DXF | |||||
| KC-10 | 2 - 75 | 2.4 | 175 | 84 | KC-10 data sheet |
DXF | |||||
| POC-200 | 2 - 130 | 2.7 | 200 | 136 | POC-200 data sheet |
DXF | |||||
| POC-400 | 4 - 300 | 3.3 | 325 | 243 | POC-400 data sheet |
DXF | |||||
| PHC-50 | hollow |
1 - 30 | 1.3 | 125 | 1000 | 26 | PHC-50 data sheet |
DXF | |||
| PHC-100 | 1 - 65 | 2.2 | 175 | 46 | PHC-100 data sheet |
DXF | |||||
DRAWINGS: PDF-Adobe Acrobat. DXF-Import into your CAD program.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fins on internal rotor move air which increases cooling with increasing RPM.
Solid shaft models - Clean, dry compressed air may be used to increase cooling.
The case has a threaded port for air connections. Threads are BSPT (tapered).
|
|
| Signal Isolation Card & Ultrasonic Sensor - For Constant Tension Unwinding & Rewinding | ||
![]() |
The ultrasonic sensor measures the diameter of the roll, to keep tension constant as roll diameter changes. The Signal Isolation Card powers the ultrasonic sensor & scales the ultrasonic's signal, for tension adjustments. The 0-10 volt signal controls your constant current power supply. | |